Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37695116

RESUMO

High-speed atomic force microscopy (HS-AFM) is a technique capable of revealing the dynamics of biomolecules and living organisms at the nanoscale with a remarkable temporal resolution. The phase delay in the feedback loop dictates the achievable speed of HS-AFM instruments that rely on fast nanopositioners operated predominantly in conjunction with piezoelectric actuators (PEAs). The high capacitance and high operating voltage of PEAs make them difficult to drive. The limited bandwidth of associated high-voltage piezo-amplifiers is one of the bottlenecks to higher scan speeds. In this study, we report a high-voltage, wideband voltage amplifier comprised of a separate amplification and novel voltage-follower power stage, requiring no global feedback. The reported amplifier can deliver a current over ±2 amps, offers a small-signal bandwidth of 1 MHz, and exhibits an exceptionally low phase lag, making it particularly well suited for the needs of next-generation HS-AFMs. We demonstrate its capabilities by reporting its achievable bandwidth under various PEA loads and showcasing its merit for HS-AFM by imaging tubulin protofilament dynamics at sub-second frame rates.

2.
Clin Microbiol Infect ; 29(2): 190-199, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35623578

RESUMO

OBJECTIVES: Matrix assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) is a widely used method for bacterial species identification. Incomplete databases and mass spectral quality (MSQ) still represent major challenges. Important proxies for MSQ are the number of detected marker masses, reproducibility, and measurement precision. We aimed to assess MSQs across diagnostic laboratories and the potential of simple workflow adaptations to improve it. METHODS: For baseline MSQ assessment, 47 diverse bacterial strains, which are challenging to identify by MALDI-TOF MS, were routinely measured in 36 laboratories from 12 countries, and well-defined MSQ features were used. After an intervention consisting of detailed reported feedback and instructions on how to acquire MALDI-TOF mass spectra, measurements were repeated and MSQs were compared. RESULTS: At baseline, we observed heterogeneous MSQ between the devices, considering the median number of marker masses detected (range = [2-25]), reproducibility between technical replicates (range = [55%-86%]), and measurement error (range = [147 parts per million (ppm)-588 ppm]). As a general trend, the spectral quality was improved after the intervention for devices, which yielded low MSQs in the baseline assessment as follows: for four out of five devices with a high measurement error, the measurement precision was improved (p-values <0.001, paired Wilcoxon test); for six out of ten devices, which detected a low number of marker masses, the number of detected marker masses increased (p-values <0.001, paired Wilcoxon test). DISCUSSION: We have identified simple workflow adaptations, which, to some extent, improve MSQ of poorly performing devices and should be considered by laboratories yielding a low MSQ. Improving MALDI-TOF MSQ in routine diagnostics is essential for increasing the resolution of bacterial identification by MALDI-TOF MS, which is dependent on the reproducible detection of marker masses. The heterogeneity identified in this external quality assessment (EQA) requires further study.


Assuntos
Bactérias , Laboratórios , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Reprodutibilidade dos Testes , Fluxo de Trabalho
3.
Micromachines (Basel) ; 12(8)2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34442564

RESUMO

We discuss distributed chemical sensing based on the swelling of coatings of optical fibers. Volume changes in the coating induce strain in the fiber's glass core, provoking a local change in the refractive index which is detectable by distributed fiber optical sensing techniques. We describe methods to realize different coatings on a single fiber. Simultaneous detection of swelling processes all along the fiber opens the possibility to interrogate thousands of differently functionalized sections on a single fiber. Principal component analysis is used to enable sensors for environmental monitoring, food analysis, agriculture, water quality monitoring, or medical diagnostics.

4.
Pulm Pharmacol Ther ; 70: 102019, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33771722

RESUMO

BACKGROUND: QMF149 is an inhaled fixed-dose combination of indacaterol acetate and mometasone furoate (MF) delivered via Breezhaler®, under development for once-daily treatment of asthma. MF delivered via Twisthaler® is approved as Asmanex® Twisthaler® for the treatment of asthma. Bridging of MF delivered via Twisthaler® to MF delivered via Breezhaler® was undertaken as part of QMF149 development to enable dose comparisons between the devices. Pharmacokinetics (PK) of MF were characterized in two studies; a single dose PK study in healthy volunteers and a pharmacokinetic/pharmacodynamic (PK/PD) study in asthma patients. OBJECTIVES: The PK study in healthy volunteers evaluated the PK of single doses of MF via Breezhaler® (50-400 µg) and compared systemic exposure of MF following administration via Breezhaler® and Twisthaler® 400 µg (2 inhalations of 200 µg). The study in patients with asthma characterized the MF PK profile following once-daily inhalation of MF via Breezhaler® and Twisthaler® devices for 4 weeks. METHODS: In the open-label, single-dose, crossover study, healthy subjects sequentially received MF via Twisthaler® (400 µg, medium-dose inhaled corticosteroid [ICS]) and escalating doses via Breezhaler® (50, 100, 200, 400 µg). PK data were obtained up to 72 h post-dose. In the double-blind, double-dummy, parallel-group study, asthma patients were randomised to receive either MF 80 µg (low-dose ICS) or 320 µg (high-dose ICS) via Breezhaler®, or 200 µg (low-dose ICS) or 800 µg (2 inhalations of 400 µg; high-dose ICS) via Twisthaler® once daily for 4 weeks. PK sampling was performed on Days 1 and 28 at pre-dose and up to 24 h post-dose. RESULTS: In the healthy volunteer PK study, 20 healthy subjects completed all treatments. Dose-normalised AUClast of MF was 1.8-1.9-fold higher when delivered via Breezhaler® versus Twisthaler®. AUC and Cmax of MF increased in a dose-proportional manner over the range of 50-400 µg via Breezhaler®. Results from this study guided dose selection of MF via Breezhaler® for the asthma study. In the asthma study, in a subset of 96 patients, mean systemic exposure (AUClast and Cmax) for MF 80 and 320 µg via Breezhaler® was comparable with MF 200 and 800 µg via Twisthaler®, respectively, on Day 28. CONCLUSION: PK characterization in a healthy volunteer PK study and subsequently an asthma study enabled selection of 80 µg (low), 160 µg (medium), and 320 µg (high) delivered via Breezhaler® as MF doses comparable to the 200 µg, 400 µg and 800 µg doses delivered by Twisthaler®, respectively, as part of QMF149 formulation development.


Assuntos
Asma , Pregnadienodiois , Administração por Inalação , Asma/tratamento farmacológico , Estudos Cross-Over , Método Duplo-Cego , Inaladores de Pó Seco , Humanos , Furoato de Mometasona
5.
Sensors (Basel) ; 21(2)2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33430229

RESUMO

Monitoring fluid flow rates is imperative for a variety of industries including biomedical engineering, chemical engineering, the food industry, and the oil and gas industries. We propose a flow meter that, unlike turbine or pressure-based sensors, is not flow intrusive, requires zero maintenance, has low risk of clogging, and is compatible with harsh conditions. Using optical fiber sensing, we monitor the temperature distribution along a fluid conduit. Pulsed heat injection locally elevates the fluid's temperature, and from the propagation velocity of the heat downstream, the fluid's velocity is determined. The method is experimentally validated for water and ethanol using optical frequency-domain reflectometry (OFDR) with millimetric spatial resolution over a 1.2 m-long conduit. Results demonstrate that such sensing yields accurate data with a linear response. By changing the optical fiber interrogation to time-domain distributed sensing approaches, the proposed technique can be scaled to cover sensing ranges of several tens of kilometers. On the other extreme, miniaturization for instance by using integrated optical waveguides could potentially bring this flow monitoring technique to microfluidic systems or open future avenues for novel "lab-in-a-fiber" technologies with biomedical applications.


Assuntos
Tecnologia de Fibra Óptica , Temperatura Alta , Fibras Ópticas , Temperatura
6.
Sensors (Basel) ; 21(3)2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33494419

RESUMO

Distributed chemical sensing is demonstrated using standard acrylate coated optical fibers. Swelling of the polymer coating induces strain in the fiber's silica core provoking a local refractive index change which is detectable all along an optical fiber by advanced distributed sensing techniques. Thermal effects can be discriminated from strain using uncoated fiber segments, leading to more accurate strain readings. The concept has been validated by measuring strain responses of various aqueous and organic solvents and different chain length alkanes and blends thereof. Although demonstrated on a short range of two meters using optical frequency-domain reflectometry, the technique can be applied to many kilometer-long fiber installations. Low-cost and insensitive to corrosion and electromagnetic radiation, along with the possibility to interrogate thousands of independent measurement points along a single optical fiber, this novel technique is likely to find applications in environmental monitoring, food analysis, agriculture, water quality monitoring, or medical diagnostics.

7.
Pulm Pharmacol Ther ; 62: 101919, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32387408

RESUMO

INTRODUCTION: Mometasone furoate (MF) is the inhaled corticosteroid (ICS) component in the long-acting ß2-agonist (LABA)/ICS fixed-dose combination of indacaterol/MF, delivered via Breezhaler®, in development for asthma. MF at low (80 µg) and high (320 µg) doses delivered via Breezhaler® is expected to be comparable to MF at low (200 µg) and high (800 µg) doses respectively, delivered via Twisthaler®. METHODS: This was a randomized, double-blind, double-dummy, four-week, parallel-group study of 739 adolescents and adults with persistent asthma. Eligible patients were receiving ICS treatment up to the maximum dose per day on a stable regimen for at least four weeks before screening. The study population was enriched for patients who were responsive to ICS therapy. The primary objective of the present study was to show non-inferiority of these doses, i.e. the low (80 µg) and high (320 µg) doses of MF delivered via Breezhaler® once daily, compared with the corresponding low (200 µg) and high (800 µg) doses of MF delivered via Twisthaler® once daily. The primary endpoint was 24 h post-dose trough forced expiratory volume in 1 s (FEV1), after four weeks of treatment in patients with asthma. A secondary objective was to evaluate the efficacy of MF 80 µg and 320 µg delivered via Breezhaler®, and MF 200 µg and 800 µg delivered via Twisthaler® in terms of Asthma Control Questionnaire-5 (ACQ-5) after one, two, three and four weeks of treatment. RESULTS: The LS mean difference in trough FEV1 after four weeks of treatment between MF low dose 80 µg (Breezhaler®) and MF low dose 200 µg (Twisthaler®) was 27 mL (95% CI -34, 89); for MF high dose 320 µg (Breezhaler®) and MF high dose 800 µg (Twisthaler®) the difference was 0 mL (95% CI -60, 61). These differences were neither clinically nor statistically significant. All treatment arms provided similar clinically relevant improvements in ACQ-5 after four weeks of treatment compared with baseline. Both treatments showed a similar safety profile with a low incidence of adverse events. CONCLUSION: The similarities in effects on lung function and ACQ after four weeks of treatment demonstrate the comparability of MF at low (80 µg) and high (320 µg) doses delivered with Breezhaler® with MF at low (200 µg) and high (800 µg) doses delivered with Twisthaler®, respectively. The study formally demonstrated that MF, delivered via Breezhaler®, is non-inferior to MF, delivered via Twisthaler® at corresponding ICS doses.


Assuntos
Antiasmáticos/administração & dosagem , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Furoato de Mometasona/administração & dosagem , Furoato de Mometasona/uso terapêutico , Administração por Inalação , Adolescente , Corticosteroides/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antiasmáticos/efeitos adversos , Método Duplo-Cego , Combinação de Medicamentos , Feminino , Humanos , Pulmão/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Furoato de Mometasona/efeitos adversos , Distribuição Aleatória , Resultado do Tratamento , Adulto Jovem
8.
Sensors (Basel) ; 21(1)2020 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-33396597

RESUMO

A high-order polynomial fitting method is proposed to accelerate the computation of double-Gaussian fitting in the retrieval of the Brillouin frequency shifts (BFS) in optical fibers showing two local Brillouin peaks. The method is experimentally validated in a distributed Brillouin sensor under different signal-to noise ratios and realistic spectral scenarios. Results verify that a sixth-order polynomial fitting can provide a reliable initial estimation of the dual local BFS values, which can be subsequently used as initial parameters of a nonlinear double-Gaussian fitting. The method demonstrates a 4.9-fold reduction in the number of iterations required by double-Gaussian fitting and a 3.4-fold improvement in processing time.

9.
Sensors (Basel) ; 19(19)2019 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-31557845

RESUMO

We developed a novel method to monitor mass flow based on distributed fiber optical temperature sensing. Examination of the temporal and spatial temperature distribution along the entire length of a locally heated fluidic conduit reveals heat flow under forced convection. Our experimental results are in good agreement with two-dimensional finite element analysis that couples fluid dynamic and heat transfer equations. Through analysis of the temperature distribution bidirectional flow rates can be measured over three orders of magnitude. The technique is not flow intrusive, works in harsh conditions, including high-temperatures, high pressures, corrosive media, and strong electromagnetic environments. We demonstrate a first experimental implementation on a short fluidic system with a length of one meter. This range covers many applications such as low volume drug delivery, diagnostics, as well as process and automation technology. Yet, the technique can, without restrictions, be applied to long range installations. Existing fiber optics infrastructures, for instance on oil pipelines or down hole installations, would only require the addition of a heat source to enable reliable flow monitoring capability.

10.
Beilstein J Nanotechnol ; 9: 1381-1389, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29977672

RESUMO

Background: Encased cantilevers are novel force sensors that overcome major limitations of liquid scanning probe microscopy. By trapping air inside an encasement around the cantilever, they provide low damping and maintain high resonance frequencies for exquisitely low tip-sample interaction forces even when immersed in a viscous fluid. Quantitative measurements of stiffness, energy dissipation and tip-sample interactions using dynamic force sensors remain challenging due to spurious resonances of the system. Results: We demonstrate for the first time electrostatic actuation with a built-in electrode. Solely actuating the cantilever results in a frequency response free of spurious peaks. We analyze static, harmonic, and sub-harmonic actuation modes. Sub-harmonic mode results in stable amplitudes unaffected by potential offsets or fluctuations of the electrical surface potential. We present a simple plate capacitor model to describe the electrostatic actuation. The predicted deflection and amplitudes match experimental results within a few percent. Consequently, target amplitudes can be set by the drive voltage without requiring calibration of optical lever sensitivity. Furthermore, the excitation bandwidth outperforms most other excitation methods. Conclusion: Compatible with any instrument using optical beam deflection detection electrostatic actuation in encased cantilevers combines ultra-low force noise with clean and stable excitation well-suited for quantitative measurements in liquid, compatible with air, or vacuum environments.

11.
Nat Commun ; 9(1): 2597, 2018 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-30013111

RESUMO

The performance of energy materials hinges on the presence of structural defects and heterogeneity over different length scales. Here we map the correlation between morphological and functional heterogeneity in bismuth vanadate, a promising metal oxide photoanode for photoelectrochemical water splitting, by photoconductive atomic force microscopy. We demonstrate that contrast in mapping electrical conductance depends on charge transport limitations, and on the contact at the sample/probe interface. Using temperature and illumination intensity-dependent current-voltage spectroscopy, we find that the transport mechanism in bismuth vanadate can be attributed to space charge-limited current in the presence of trap states. We observe no additional recombination sites at grain boundaries, which indicates high defect tolerance in bismuth vanadate. These findings support the fabrication of highly efficient bismuth vanadate nanostructures and provide insights into how local functionality affects the macroscopic performance.


Assuntos
Bismuto/química , Nanoestruturas/química , Energia Solar , Vanadatos/química , Água/química , Condutividade Elétrica , Eletrodos , Microscopia de Força Atômica , Processos Fotoquímicos , Semicondutores , Análise Espectral/métodos
12.
Agric Ecosyst Environ ; 261: 161-171, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29970945

RESUMO

Cowpea (Vigna unguiculata L. Walp.) is an important African food legume suitable for dry regions. It is the main legume in two contrasting agro-ecological regions of Kenya as an important component of crop rotations because of its relative tolerance to unpredictable drought events. This study was carried out in an effort to establish a collection of bacterial root nodule symbionts and determine their relationship to physicochemical soil parameters as well as any geographical distributional patterns. Bradyrhizobium spp. were found to be widespread in this study and several different types could be identified at each site. Unique but rare symbionts were recovered from the nodules of plants sampled in a drier in-land region, where there were also overall more different bradyrhizobia found. Plants raised in soil from uncultivated sites with a natural vegetation cover tended to also associate with more different bradyrizobia. The occurrence and abundance of different bradyrhizobia correlated with differences in soil texture and pH, but did neither with the agro-ecological origin, nor the origin from cultivated (n = 15) or uncultivated (n = 5) sites. The analytical method, protein profiling of isolated strains by Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS), provided higher resolution than 16S rRNA gene sequencing and was applied in this study for the first time to isolates recovered directly from field-collected cowpea root nodules. The method thus seems suitable for screening isolate collections on the presence of different groups, which, provided an appropriate reference database, can also be assigned to known species.

13.
Appl Microbiol Biotechnol ; 102(12): 5265-5278, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29696334

RESUMO

Cowpea N2 fixation and yield can be enhanced by selecting competitive and efficient indigenous rhizobia. Strains from contrasting agro-ecologies of Kilifi and Mbeere (Kenya) were screened. Two pot experiments were established consisting of 13 Bradyrhizobium strains; experiment 1 (11 Mbeere + CBA + BK1 from Burkina Faso), experiment 2 (12 Kilifi + CBA). Symbiotic effectiveness was assessed (shoot biomass, SPAD index and N uptake). Nodule occupancy of 13 simultaneously co-inoculated strains in each experiment was analyzed by matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry (MS) to assess competitiveness. Strains varied in effectiveness and competitiveness. The four most efficient strains were further evaluated in a field trial in Mbeere during the 2014 short rains. Strains from bacteroids of cowpea nodules from pot and field experiments were accurately identified as Bradyrhizobium by MALDI-TOF based on the SARAMIS™ database. In the field, abundant indigenous populations 7.10 × 103 rhizobia g-1 soil, outcompeted introduced strains. As revealed by MALDI-TOF, indigenous strains clustered into six distinct groups (I, II, III, IV, V and VI), group III were most abundant occupying 80% of nodules analyzed. MALDI-TOF was rapid, affordable and reliable to identify Bradyrhizobium strains directly from nodule suspensions in competition pot assays and in the field with abundant indigenous strains thus, its suitability for future competition assays. Evaluating strain competitiveness and then symbiotic efficacy is proposed in bioprospecting for potential cowpea inoculant strains.


Assuntos
Bradyrhizobium/química , Bradyrhizobium/fisiologia , Técnicas Microbiológicas/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Vigna/microbiologia , Bradyrhizobium/classificação , Quênia , Nódulos Radiculares de Plantas/microbiologia
14.
Front Microbiol ; 7: 1793, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27891120

RESUMO

In smallholder farms of Côte d'Ivoire, particularly in the northeast of the country, Cajanus cajan (pigeonpea) has become an important crop because of its multiple beneficial facets. Pigeonpea seeds provide food to make ends meet, are sold on local markets, and aerial parts serve as forage for animals. Since it fixes atmospheric nitrogen in symbiosis with soil bacteria collectively known as rhizobia, C. cajan also improves soil fertility and reduces fallow time. Yet, seed yields remain low mostly because farmers cannot afford chemical fertilizers. To identify local rhizobial strains susceptible to be used as bio-inoculants to foster pigeonpea growth, root nodules were collected in six fields of three geographically distant regions of Côte d'Ivoire. Nodule bacteria were isolated and characterized using various molecular techniques including matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry (MS) and DNA sequencing. These molecular analyses showed that 63 out of 85 nodule isolates belonged to two major clades of bradyrhizobia, one of which is known as the Bradyrhizobium elkanii super clade. Phylogenies of housekeeping (16S-ITS-23S, rpoB) and symbiotic (nifH) genes were not always congruent suggesting that lateral transfer of nitrogen fixation genes also contributed to define the genome of these bradyrhizobial isolates. Interestingly, no field-, plant-, or cultivar-specific effect was found to shape the profiles of symbiotic strains. In addition, nodule isolates CI-1B, CI-36E, and CI-41A that belong to distinct species, showed similar symbiotic efficiencies suggesting that any of these strains might serve as a proficient inoculant for C. cajan.

15.
Front Microbiol ; 7: 2150, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28119675

RESUMO

TaqMan-based quantitative PCR (qPCR) assays were developed to study the persistence of two well-characterized strains of plant growth-promoting rhizobacteria (PGPR), Pseudomonas fluorescens Pf153 and Pseudomonas sp. DSMZ 13134, in the root and rhizoplane of inoculated maize plants. This was performed in pot experiments with three contrasting field soils (Buus, Le Caron and DOK-M). Potential cross-reactivity of the qPCR assays was assessed with indigenous Pseudomonas and related bacterial species, which had been isolated from the rhizoplane of maize roots grown in the three soils and then characterized by Matrix-Assisted Laser Desorption Ionization (MALDI) Time-of-Flight (TOF) mass spectrometry (MS). Sensitivity of the qPCR expressed as detection limit of bacterial cells spiked into a rhizoplane matrix was 1.4 × 102 CFU and 1.3 × 104 CFU per gram root fresh weight for strain Pf153 and DSMZ 13134, respectively. Four weeks after planting and inoculation, both strains could readily be detected in root and rhizoplane, whereas only Pf153 could be detected after 8 weeks. The colonization rate of maize roots by strain Pf153 was significantly influenced by the soil type, with a higher colonization rate in the well fertile and organic soil of Buus. Inoculation with strain DSMZ 13134, which colonized roots and rhizoplane to the same degree, independently of the soil type, increased yield of maize, in terms of biomass accumulation, only in the acidic soil of Le Caron, whereas inoculation with strain Pf153 reduced yield in the soil Buus, despite of its high colonization rate and persistence. These results indicate that the colonization rate and persistence of inoculated Pseudomonas strains can be quantitatively assessed by the TaqMan-based qPCR technique, but that it cannot be taken for granted that inoculation with a well-colonizing and persistent Pseudomonas strain has a positive effect on yield of maize.

16.
Appl Microbiol Biotechnol ; 99(13): 5547-62, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25776061

RESUMO

Accurate identification of soil bacteria that form nitrogen-fixing associations with legume crops is challenging given the phylogenetic diversity of root nodule bacteria (RNB). The labor-intensive and time-consuming 16S ribosomal RNA (rRNA) sequencing and/or multilocus sequence analysis (MLSA) of conserved genes so far remain the favored molecular tools to characterize symbiotic bacteria. With the development of mass spectrometry (MS) as an alternative method to rapidly identify bacterial isolates, we recently showed that matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) can accurately characterize RNB found inside plant nodules or grown in cultures. Here, we report on the development of a MALDI-TOF RNB-specific spectral database built on whole cell MS fingerprints of 116 strains representing the major rhizobial genera. In addition to this RNB-specific module, which was successfully tested on unknown field isolates, a subset of 13 ribosomal proteins extracted from genome data was found to be sufficient for the reliable identification of nodule isolates to rhizobial species as shown in the putatively ascribed ribosomal protein masses (PARPM) database. These results reveal that data gathered from genome sequences can be used to expand spectral libraries to aid the accurate identification of bacterial species by MALDI-TOF MS.


Assuntos
Bactérias/química , Bactérias/classificação , Biodiversidade , Proteínas Ribossômicas/análise , Nódulos Radiculares de Plantas/microbiologia , Microbiologia do Solo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias/genética , Proteínas de Bactérias/genética , Biomarcadores/análise , Análise por Conglomerados , DNA Ribossômico/química , DNA Ribossômico/genética , Dados de Sequência Molecular , Filogenia , RNA Ribossômico 16S/genética , Análise de Sequência de DNA
17.
J Dairy Sci ; 97(1): 240-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24210492

RESUMO

Airborne communities (mainly bacteria) were sampled and characterized (concentration levels and diversity) at 1 outdoor and 6 indoor sites within a Swiss dairy production facility. Air samples were collected on 2 sampling dates in different seasons, one in February and one in July 2012 using impaction bioaerosol samplers. After cultivation, isolates were identified by mass spectrometry (matrix-assisted laser desorption/ionization-time-of-flight) and molecular (sequencing of 16S rRNA and rpoB genes) methods. In general, total airborne particle loads and total bacterial counts were higher in winter than in summer, but remained constant within each indoor sampling site at both sampling times (February and July). Bacterial numbers were generally very low (<100 cfu/m(3) of air) during the different steps of milk powder production. Elevated bacterial concentrations (with mean values of 391 ± 142 and 179 ± 33 cfu/m(3) of air during winter and summer sampling, respectively; n=15) occurred mainly in the "logistics area," where products in closed tins are packed in secondary packaging material and prepared for shipping. However, total bacterial counts at the outdoor site varied, with a 5- to 6-fold higher concentration observed in winter compared with summer. Twenty-five gram-positive and gram-negative genera were identified as part of the airborne microflora, with Bacillus and Staphylococcus being the most frequent genera identified. Overall, the culturable microflora community showed a composition typical and representative for the specific location. Bacterial counts were highly correlated with total airborne particles in the size range 1 to 5 µm, indicating that a simple surveillance system based upon counting of airborne particles could be implemented. The data generated in this study could be used to evaluate the effectiveness of the dairy plant's sanitation program and to identify potential sources of airborne contamination, resulting in increased food safety.


Assuntos
Microbiologia do Ar , Bactérias Aeróbias/isolamento & purificação , Bactérias/isolamento & purificação , Indústria de Laticínios/métodos , Leite/microbiologia , Animais , Bactérias/classificação , Bactérias Aeróbias/classificação , Carga Bacteriana , Contaminação de Alimentos/análise , Microbiologia de Alimentos , Genes Bacterianos , RNA Ribossômico 16S/genética , Estações do Ano , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
18.
Ultramicroscopy ; 137: 48-54, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24295799

RESUMO

We propose a novel method to detect and correct drift in non-raster scanning probe microscopy. In conventional raster scanning drift is usually corrected by subtracting a fitted polynomial from each scan line, but sample tilt or large topographic features can result in severe artifacts. Our method uses self-intersecting scan paths to distinguish drift from topographic features. Observing the height differences when passing the same position at different times enables the reconstruction of a continuous function of drift. We show that a small number of self-intersections is adequate for automatic and reliable drift correction. Additionally, we introduce a fitness function which provides a quantitative measure of drift correctability for any arbitrary scan shape.

19.
ACS Nano ; 7(9): 8258-65, 2013 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23987138

RESUMO

Using Kelvin probe force microscopy (KPFM) we studied the local charge trapping states at the SiO2-oligothiophene interface in a field effect transistor (FET), where SiO2 is the gate dielectric. KPFM reveals surface potential inhomogeneities within the oligothiophene monolayer, which correlate with its structure. A large peak of trap states with energies in the oligothiophene's band gap due to hydroxyl groups is present at the oxide surface. We show that these states are successfully eliminated by preadsorption of a layer of (3-aminopropyl)triethoxysilane (APTES). Time-resolved surface potential transient measurements further show that the charge carrier injection in the nonpassivated FET contains two exponential transients, due to the charge trapping on the oxide surface and in the bulk oxide, while the APTES-passivated FET has only a single-exponential transient due to the bulk oxide. The results demonstrate that APTES is a good SiO2 surface passivation layer to reduce trap states while maintaining a hydrophilic surface, pointing out the importance of dielectric surface passivation to bridge the gap between soft materials and electronic devices.

20.
Nanotechnology ; 24(33): 335703, 2013 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-23892397

RESUMO

Scanning probe microscopy (SPM) has facilitated many scientific discoveries utilizing its strengths of spatial resolution, non-destructive characterization and realistic in situ environments. However, accurate spatial data are required for quantitative applications but this is challenging for SPM especially when imaging at higher frame rates. We present a new operation mode for scanning probe microscopy that uses advanced image processing techniques to render accurate images based on position sensor data. This technique, which we call sensor inpainting, frees the scanner to no longer be at a specific location at a given time. This drastically reduces the engineering effort of position control and enables the use of scan waveforms that are better suited for the high inertia nanopositioners of SPM. While in raster scanning, typically only trace or retrace images are used for display, in Archimedean spiral scans 100% of the data can be displayed and at least a two-fold increase in temporal or spatial resolution is achieved. In the new mode, the grid size of the final generated image is an independent variable. Inpainting to a few times more pixels than the samples creates images that more accurately represent the ground truth.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...